Help · version 1.0
Messages
ContentsWhat X3 says, grouped by where you meet it, and what to do about it. To find a message, search the page for a few of its words: a word in italics stands for what X3 fills in, such as a project’s number. The installation check’s messages are in the install guide.
Running the collector
| Message | What to do |
|---|---|
| No run yet: run the collector to take the folder’s inventory. | Press Run collector. |
| Collector run run finished: count developments, count dependencies, readiness score. | Nothing: the page shows the run. With the partner’s key alone, A fingerprint needs an upgrade key… follows, and the run leaves no fingerprint. |
| Collector run run is still running. Try again when it has finished. | Wait for the run, then press the button again. |
| Collector run run failed: reason | Read the reason, then run it again. |
| The collector could not start: reason | Read the reason, then run it again. |
| The fingerprint file file could not be written: reason | Check the folder’s directory on the server and its rights, then run again. |
| Collector run run is marked as running, but no process runs it. | The run stopped without ending: run the collector again. |
Downloading the fingerprint
| Message | What to do |
|---|---|
| No fingerprint file yet: run the collector first. | Press Run collector. With the partner’s key alone a run writes no fingerprint: paste the upgrade key first. |
| The file file is not there any more: run the collector again. | Press Run collector. |
| The file file could not be downloaded, X3’s answer answer. | Try again. If it comes back, tell Nortiqo with X3’s answer. |
Importing a fingerprint
Import fingerprint shows these. It imports the whole file or nothing, so an import that is refused or fails leaves no project behind.
| Message | What to do |
|---|---|
| Project project imported: count lines, count broken, count at risk. | Nothing: the project is first in Projects. Open its task list with Upgrade findings in the line’s Actions. |
| Give the fingerprint file’s name. | Enter the name in Fingerprint file. |
| File file was not found. | Put the file in this folder’s directory on the server, or correct its name. |
| file is not a fingerprint file. | Choose the file Download fingerprint saved. |
| file is of fingerprint format format, which this version does not read. | Install the same version of Nortiqo Upgrade in both folders. |
| file is incomplete: count lines of kind kind read, count expected. Nothing was imported. | The file was cut on its way: copy it again. |
| The import of file failed: reason | Nothing was imported. Read the reason, then import again. |
| the file changed while it was read; import it again. | Import the file again once nothing writes to it any more. |
The task list
| Message | What to do |
|---|---|
| Project project no longer exists. | Open the task list again from the project’s line in Upgrade projects, which lists every project there is. |
| count lines in this selection, lines first–last shown. Next page and Previous page show the rest. | Nothing: Next page and Previous page show the rest, or type a line in First line and refresh the list. |
| No findings for this selection. | Widen the selection: untick Open only, or empty Development. |
| This is the first page. | Nothing: the list starts at the selection’s first line. |
| This is the last page. | Nothing: no line of the selection follows those shown. |
| Report file written: count lines. | Nothing: open the file in Excel from your browser and send it on. |
| The file file could not be downloaded, X3’s answer answer. | Try again. If it comes back, tell Nortiqo with X3’s answer. |
What changed on a line
Each of these is the text of a line’s What changed, in the window and in the report: why the line has its finding.
| Message | What to do |
|---|---|
| element no longer exists. | Change the development so that it no longer relies on what is gone, then set the line to Fixed. |
| script no longer raises entry point. | Change the development to fit the new release, then set the line to Fixed. |
| Compiled script script changed. | Test where What to test says, then set the line to Tested. |
| routine takes count parameters; count arguments are given. | Change the development to fit the new release, then set the line to Fixed. |
| Parameter number of routine is now type, was type. | Change the development to fit the new release, then set the line to Fixed. |
| Abbreviation now abbreviation, was abbreviation. | Change the development to fit the new release, then set the line to Fixed. |
| Type now type, was type. | Change the development to fit the new release, then set the line to Fixed. |
| Length now length, was length. | When it is now smaller, the line is Broken: change the development to fit, then set the line to Fixed. When larger, the line is At risk, test it: test where What to test says, then set the line to Tested. |
| Dimension now dimension, was dimension. | When it is now smaller, the line is Broken: change the development to fit, then set the line to Fixed. When larger, the line is At risk, test it: test where What to test says, then set the line to Tested. |
| Its own lines changed. | Test where What to test says, then set the line to Tested. |
| Sage’s script changed; the folder’s copy hides the change. | Remove the folder’s copy and test what the script serves, as What to test says, then set the line to Tested. |
| Activity code code is not active in this folder. | Activate it in the reference folder, as in the customer’s, and import again. |
| Module module is not active in this folder. | Activate the module in the reference folder and import again. |
| Legislation legislation of the customer’s folder is not in this folder. | Set the reference folder up with the legislation and import again. |
| script could not be read in this folder. | Check that the reference folder holds Sage’s file, then import again. |
| The collector could not resolve this use. | Check the use by hand in the script the line names. |
Pasting a key
General parameters shows these as it refuses the value pasted, and nothing is saved.
| Message | What to do |
|---|---|
| This is not a licence key of Nortiqo Upgrade: check that the whole key was pasted. | Paste the whole line Nortiqo sent, with nothing missing. An upgrade key goes on XNQUUPGKEY (The licence keys). |
| This is not an upgrade key of Nortiqo Upgrade: check that the whole key was pasted. | Paste the whole line Nortiqo sent, with nothing missing. The partner’s yearly key goes on XNQUKEY. |
| This upgrade key is made for folder code code, and this folder’s code is code. | Paste the key made for this folder, or order one for the code Upgrade code shows. |
| This folder has no upgrade code yet: open Upgrade readiness, which makes it. | Open Upgrade readiness, then paste the key again. |
The key’s state
Upgrade readiness shows these as it opens, or on Run collector and Download fingerprint.
| Message | What to do |
|---|---|
| Nortiqo Upgrade has no licence key, so the collector does not run: paste the key in XNQUKEY or XNQUUPGKEY. | Paste the partner’s key in XNQUKEY, or the upgrade key in XNQUUPGKEY. |
| Parameter parameter holds no key of Nortiqo Upgrade for this folder, so the collector does not run. | Paste the key Nortiqo sent, whole, in the parameter named; an upgrade key works only in the folder of its code. |
| The Nortiqo Upgrade key in parameter, customer customer, is paid through date: paste a renewed key by then. | Order the renewal, and paste the new key before the date named. |
| The key in parameter, customer customer, was paid through date. The collector runs until last day: paste a renewed key. | Paste a renewed key by the last day named; after it, the collector stops. |
| The collector does not run: the key in parameter, customer customer, was paid through date. Paste a renewed key. | Paste a renewed key, then run the collector. |
| A fingerprint needs an upgrade key made for this folder’s code code, which the partner orders from Nortiqo. | Order the upgrade key with the code named, and paste it in XNQUUPGKEY. |
Stuck? Ask your Sage partner, or write to info@nortiqo.com.