Every save and every deletion in Signing roles and Signature policies is signed before anything is written.

  1. The signer’s right is checked first, then the record’s own checks. While your signing is locked, the save is refused with the message that it is locked; when you may not sign the change, X3 says which role kind signs it.
  2. The signing dialog shows every value the save changes. A role shows its description, kind and active flag, and each grant’s user, start and end, the grant’s line named by its user and start. A policy shows its own fields, each governed field, each step’s columns, each condition line’s number, field, test, values, From and To, the line named by its number, and its version. A creation shows every value new, a deletion every value old, and a line changed only the values that changed. A check box shows as 1 (No) or 2 (Yes), a choice from a list by its number, and a date as DD/MM/YYYY.
  3. Sign with your user code and signing code: the record is saved, with a change set Applied and its entry in the register. Close the dialog instead: nothing is saved.

Who signs. A role’s change is signed by a holder of a grant in force of a role of kind Role administrators; a policy’s, of kind Policy administrators. While nobody holds such a grant, whoever saves signs, so that a folder’s first administrator can start: create the role administrators’ role first, with your own grant, then the policy administrators’. Keep at least one administrator’s grant with no end: should every grant of a kind lapse, or its role be made inactive, anyone who may open the function signs its changes again.

Nothing of the setup is saved unsigned: an import, a web service or a batch cannot change it. A copy is signed as a creation.

No key change. Signature meanings, Signing roles and Signature policies offer no Key change: the steps, the grants, the change sets and the register name a meaning, a role or a policy by its code, and an entry of the register is never rewritten. To rename one, create it again under the new code and make the old one inactive.

A save is also refused when it changes more values than a signature shows, when a value is longer than a change set holds, or when no seal certificate is named. When another signature is recorded at the same moment, save again.