← Nortiqo E-signature

Install guide · version 1.0

1. Check the folder

Contents

The check patch reads the folder and reports whether anything stands in the way of the patch of step 2. It stops while the parameter chapter or group is missing, which the patch cannot bring, so they are added by hand first.

  1. The parameter chapter and group. In GESADI, enter 901 in Table, the parameter chapters. If no line has code XNQ, add one with Insert in a line’s Actions, and save: where another Nortiqo product is installed, it is there already. Then enter 903, the parameter groups, and if no line has code XNQE, add one the same way, and save.

    Table Code Description Short description
    901 XNQ Nortiqo Nortiqo
    903 XNQE Nortiqo E-signature E-signature
  2. Activity code AUDIT. In GESACV, check that activity code AUDIT is active: X3’s audit, which the integrity monitor reads (step 9), works only while it is. If it is not, make it active now, before the patch: in GESADS, from the parent folder, in the folder’s record, then validate the folder. If AUDIT is made active only after the patch, tell Nortiqo: whether the patch’s own tables then need a validation of their own is not known yet.

  3. The check patch. In function PATCH, Destination type Client, upload Nortiqo-ESignature-1-0-0-check under the name it has, and choose the customer’s folder alone in the grid. Run PATCH from a session of that folder. Check Patch integration, leave Deferred validation and Link synchronization unchecked, and run it, with no simulation first: in a first installation its simulation ends in error, since the scripts it runs are not yet in the folder.

Check: the log’s lines from Nortiqo E-signature, the check of folder … end with Nothing stands in the way: go.

  • A line … problems found: stop. comes after a line for each problem, such as a table of ours under another activity code, a module the folder does not use, or a window where no code is free for the menu: stop, and tell Nortiqo with the log.
  • A line that the parameter chapter XNQ or group XNQE is missing means point 1 is not done: do it, then integrate a copy of the check patch renamed Nortiqo-ESignature-1-0-0-chk2, or -chk3 a third time, as in point 3.
  • A window whose object’s module the folder does not use is passed over with a line, such as the routing’s OROU where Manufacturing is not used; that stops nothing.
  • In a first installation each line shows its message’s code and its values in place of its text, since the texts come with the patch of step 2: X3_76 and the folder first, then X3_90 last for go, or X3_91 and the count of problems for stop. A missing chapter is X3_251 XNQ, a missing group X3_252 XNQE. The log’s lines by code, at the end of this guide, gives the line of each code.

Stuck? Ask your Sage partner, or write to info@nortiqo.com.