Install guide · version 1.0
The log's lines by code
ContentsThe lines the check and the installer write in PATCH’s log. In a first installation
the check’s lines show as their codes with their values after them, in the order of $1$, $2$
and $3$ below (step 1). A line marked a stop ends the check with X3_91: nothing is
written, and the line says what stands in the way.
| Code | The line | Written by |
|---|---|---|
X3_76 |
Nortiqo E-signature, the check of folder $1$ | The check, its first line |
X3_77 |
Activity code $1$ is not in the folder: a first installation. | The check |
X3_78 |
Activity code $1$ and table $2$ are in the folder: an update. | The check |
X3_79 |
Activity code $1$ is in the folder without table $2$. | The check, a stop |
X3_80 |
$1$ $2$ has activity code $3$, not that of Nortiqo E-signature. | The check, a stop |
X3_81 |
$1$ $2$ is in the folder before Nortiqo E-signature is. | The check, a stop |
X3_82 |
Script $1$ is in the folder before Nortiqo E-signature is. | The check, a stop |
X3_83 |
Chapter or local menu $1$ has activity code $2$, not that of Nortiqo E-signature. | The check, a stop |
X3_84 |
Module $1$ is not used in this folder. | The check, a stop |
X3_85 |
Window $1$: menu $2$ with its line $3$ is in place. | The check |
X3_86 |
Window $1$: menu $2$ with the line $3$ is to be added. | The check |
X3_87 |
Window $1$: no code is free for a menu and its line. | The check, a stop |
X3_88 |
Window $1$: menu $2$ of Nortiqo E-signature is not whole; remove it, then install again. | The check, a stop: tell Nortiqo with the log, which sends the removal patch |
X3_89 |
Entry point on object $1$: script $2$, activity code $3$. | The check |
X3_90 |
Nothing stands in the way: go. | The check, its last line |
X3_91 |
$1$ problems found: stop. | The check, its last line, a stop |
X3_92 |
Folder $1$ is the reference folder: nothing is checked or written there. | The check and the installer |
X3_93 |
Folder $1$ is not this session’s folder, $2$: run PATCH from folder $1$. | The check and the installer, a stop |
X3_94 |
Simulation: nothing is written. | The installer |
X3_95 |
Nothing is written, since the check found problems. | The installer |
X3_96 |
Window $1$: menu $2$ with the line $3$ added. | The installer |
X3_97 |
Window $1$ validated. | The installer |
X3_98 |
Window $1$ could not be validated. | The installer, an error |
X3_99 |
Window $1$: the lines could not be written, and nothing was. | The installer, an error |
X3_100 |
Text $1$ is not in the folder. | The check, a stop |
X3_186 |
Window $1$ is passed over: module $2$ is not used in this folder. | The check |
X3_251 |
Parameter chapter $1$ is not in miscellaneous table 901: add it in GESADI before the patch. | The check, a stop |
X3_252 |
Parameter group $1$ is not in miscellaneous table 903: add it in GESADI before the patch. | The check, a stop |
X3_255 |
Template $1$ is as Nortiqo E-signature ships it. | The installer |
X3_256 |
Template $1$ is missing or not as Nortiqo E-signature ships it. | The installer, an error |
X3_257 |
Template $1$ could not be checked: $2$. | The installer |
Stuck? Ask your Sage partner, or write to info@nortiqo.com.